An optional Real-Time Gage Module can be combined with SPC-PC IV to allow direct reading of data from measurement devices through the RS-232 port. To make life a little easier, the Real-Time Gage Module contains a list of commonly used gages and multiplexors with pre-defined factory specifications (baud rate, parity, etc.). Simply select the desired measurement device from the list, designate the placement of the data in SPC-PC IV, and begin taking readings. The list includes devices from manufacturers such as Starrett, Fowler, and Mitutoyo; if your device is not listed, the Real-Time Gage Module offers a 'Generic' setting to enter the specifications unique to your device.
In addition, the Gage Module has features to automatically enter the time and date of each reading, verify the reading against a pre-determined range to guard against gage or operator error, and add or delete leading or trailing values. It is possible to continuously monitor your processes since SPC-PC IV updates all charts to include the new data as it is read from the gage. Furthermore, while in real time mode, the operator will have full access to the data set in order to add notes, tag line information, and attach assignable causes.
The supported gages and their manufacturer are listed below:
Starrett
Starrett 741: The Starrett 741 Multiplexor
will interface with any gage with RS-232
output.
Starrett 742: Data
Collector
Starrett 772: Data
Collector
Any Starrett gage that can plug into
their serial port
adapter.
Mitutoyo
MIG-2: The MIG-2 Multiplexor will interface
with all Mitutoyo gages that have SPC
support.
MUX-10: The MUX-10 Multiplexor will
interface with all Mitutoyo gages that have SPC
support.
WRU-U1: The Mitutoyo WRU-U1 will interface
with any gage capable of being equipped with the TXU-MNU transmitter
unit.
Gage Talker
GagePort NT & GagePort 2220:
The GagePort NT & GagePort 2220 will interface with the following gages
Mitutoyo (Footswitch and Gage button
send modes)
Federal Maxum (Footswitch
Mode)
Ultra Cal II (Footswitch
Mode)
Brown & Sharpe Data Hite (Gage button
send mode)
Brown & Sharpe Digit Cal II (Gage
button send mode)
Brown & Sharpe Digit Cal Plus
(Footswitch and Gage button send
modes)
Brown & Sharpe Dial II (Footswitch
mode)
Brown & Sharpe Digit Hite Plus
(Footswitch and Gage button send
modes)
Brown & Sharpe Digit Dial Plus
(Footswitch mode)
Brown & Sharpe Intermik Plus (Footswitch
and Gage button send modes)
Brown & Sharpe Micro EBG (Gage button
send mode)
Limited RS-232 (Gage button send
mode)
Fowler
Supports any Fowler Gage that has RS-232
output.
Boeckler
Boeckler Microcode II: Will interface
with all Boeckler
Gages.
Quality Measurement
Systems
Genesis QA2500 Data
Collector
Genesis QA300 Data
Collector